Intake strainers, Verify all gauges are in working order, Operate pump controls – Hale Q Series Muscle User Manual

Page 77: Inspect water and foam tanks, Check auxiliary engine, 5 monthly

Advertising
background image

75

MUSCLE (Midship) Pumps Installation, Operation, and Maintenance Manual
p/n: 029-0020-63-0

Preventive Maintenance

Note: The PMD valve should be lubricated every six (6) months.

Intake Strainers

Check and clean any debris from the intake.

Flush the pump, if required, using departmental/company procedures.

Repair or replace any damaged strainers.

Verify All Gauges are in Working Order

Any gauge that is repeated in the cab or another panel, must agree with the gauge on
the operator's panel. Gauges not reading within 10% of the calibrated test gauge must
be removed from service and re-calibrated.

Operate Pump Controls

Operate the pump drive controls to verify the pump engages. Verify the indicator lights
work properly.

Inspect Water and Foam Tanks

Inspect water and foam tanks for proper level and gauge readings. If any debris is
present, flush the tanks to protect the pump from wear caused by dirty water or foam
concentrate.

Check Auxiliary Engine

See engine manufacturer’s manual for wear and proper operation.

5.5 MONTHLY

Monthly maintenance includes the weekly maintenance procedures plus:

Valve lubrication - see page 76

Suction Check Valve testing - see page 76

Gearbox lubrication - see page 76

Dry vacuum testing - see page 78

Checking the pump and drive line bolts - see page 77

Advertising
This manual is related to the following products:

8FG