Troubleshooting

Insufficient Pump
Capacity, Dual-
Stage.

Transfer valve not in
proper position for
operation, based on
capacity rating and
pressure.

• Place transfer valve in VOLUME position (parallel) when pumping

more than 1/2 rated capacity.

• For pressure above 200 PSI (141379 kPa), pump should be

placed in PRESSURE (series) position.

• For operating procedures, review Section 4 “Basic Operation,”

beginning on page 53.

• For Transfer Valve test, review Section 4, heading “Transfer Valve

Test (Two-Stage Pumps Only),” beginning on page 73.

Insufficient Pres-
sure.

Insufficient engine
power.

• See previous heading “Insufficient Pump Capacity, Single Stage.”

on page 96.

Two-Stage Pump Only
-

Transfer valve not in
proper position for
operation, based on
capacity rating and
pressure.

• Two-Stage Pump Only -

• Place transfer valve in PRESSURE position (series) when pump-

ing pressures above 200 PSI (1379 kPa).

• For operating procedures, review Section 4 “Basic Operation,”

beginning on page 53.

• For Transfer Valve test, review Section 4, heading “Transfer Valve

Test (Two-Stage Pumps Only),” beginning on page 73.

Leak at Pump
Packing.

Packing out of adjust-
ment or worn.

• Readjust packing for 8 to 10 drops per minute leakage at 150 PSI

(1000 kPa).

• Packing replacement is recommended every two to three years,

depending on usage.

• See Section 4 Preventive Maintenance, heading “Packing Gland

Adjustment” on page 77.

Remote Control
Difficult to Oper-
ate.

Lack of lubrication.

• Lubricate the remote control linkages and collar with oil.