JLG 1100S Service Manual User Manual

Page 108

Advertising
background image

SECTION 3 - CHASSIS & TURNTABLE

3-66

– JLG Lift –

3121256

11. Assemble wear plate (9) over the drive link (10) and

alignment studs onto the housing (18).

12. Apply a small amount of clean grease to a new seal

ring (4) and assemble it into the seal ring groove on
the wear plate side of the rotor set stator (8B).

13. Install the assembled rotor set (8) onto wear plate

(9) with rotor (8A) counterbore and seal ring side
down and the splines into mesh with the drive link
splines.

NOTE: It may be necessary to turn one alignment stud out

of the housing (18) temporarily to assemble rotor set
(8) or manifold (7) over the drive link.

NOTE: If necessary, go to the appropriate, “Rotor Set Com-

ponent Assembly Procedure.”

NOTE: The rotor set rotor counterbore side must be down

against wear plate for drive link clearance and to
maintain the original rotor-drive link spline contact. A
rotor set without a counterbore and that was not
etched before disassembly can be reinstalled using
the drive link spline pattern on the rotor splines if
apparent, to determine which side was down.The
rotor set seal ring groove faces toward the wear plate
(9).

14. Apply clean grease to a new seal ring (4) and

assemble it in the seal ring groove in the rotor set
contact side of manifold (7).