JLG 1100S Service Manual User Manual

Page 23

Advertising
background image

SECTION 1 - SPECIFICATIONS

3121256

– JLG Lift –

1-7

4. Wheel Hub

Lube Point(s) - Level/Fill Plug
Capacity - 0.5 quarts (0.5 liters) ± 10%
Lube - EPGL
Interval - Change after first 150 hours then every

1200 hours of operation

Comments - Place Fill port at 12 o’clock position

and Check port at 3 o’clock position. Pour lubri-
cant into fill port until it just starts to flow out of
check port.

5. Hydraulic Return Filter

Lube Point(s) - Replaceable Element
Interval - Change after first 50 hours and every 300

hours thereafter or as indicated by condition indi-
cator

6. Hydraulic Charge Filter

Lube Point(s) - Replaceable Element
Interval - Change after first 50 hours and every 300

hours thereafter or as indicated by condition indi-
cator.

7. Hydraulic Oil

Lube Point(s) - Fill Cap
Capacity - 55 gallons (208 liters) Tank
Lube - HO
Interval - Check level daily with boom down, axles

retracted, cylinders retracted. Change every 2
years or 1200 hours of operation.

FULL LEVEL (HOT OIL)

FULL LEVEL (COLD OIL)