Deutz engine dipstick -8 – JLG 1100S Service Manual User Manual

Page 24

Advertising
background image

SECTION 1 - SPECIFICATIONS

1-8

– JLG Lift –

3121256

8. Suction Strainers (In Tank)

Lube Point(s) - 2
Interval - Every 2 years or 1200 hours of operation.

Remove and clean at time of hydraulic oil
change.

9. Oil Change w/Filter - Deutz

Lube Point(s) - Fill Cap/Spin-on Element
Capacity -
5 Quarts (4.5 L) Cooling System
11 Quarts (10.5 L) Engine w/Filter
16 Quarts (15 L) Total Capacity
Lube - EO
Interval - Check level daily; change every 500 hours

or six months, whichever comes first. Adjust final
oil level by mark on dipstick. Refer to Figure 1-2.,
Deutz Engine Dipstick.

10. Fuel Filter - Deutz

Lube Point(s) - Replaceable Element
Interval - Every year or 600 hours of operation

MINIMUM LEVEL,
OIL HOT

MINIMUM OIL
LEVEL

MINIMUM LEVEL,
OIL COLD

NOTE: Hot oil checks should not be made until the engine
has been shut down for a period of 5 minutes.

MAXIMUM LEVEL,
OIL HOT

MAXIMUM LEVEL,
OIL COLD

MAXIMUM OIL

LEVEL

Figure 1-2. Deutz Engine Dipstick

Advertising