SECTION 5 - HYDRAULICS

3121256

– JLG Lift –

5-43

6. Remove the adjustment shim.

7. Unscrew the cap nut and remove it.

8. Loosen the fixing nut of the stopper max flow and

disassemble it.

9. Turn in the stopper max flow to get swivel angle

zero.

10. Disassemble the rotary group in horizontal position.

11. Disassemble the stopper max flow.

12. Remove the threaded pin.

13. Disassemble the plug.