JLG 1100S Service Manual User Manual

Page 299

Advertising
background image

SECTION 6 - JLG CONTROL SYSTEM

3121256

– JLG Lift –

6-25

GROUND
MODE:

U. LIFT UP XXX%

Displays/adjusts fixed main lift up speed 0 to 100%

60

60

U. LIFT DN XXX%

Displays/adjusts main lift down speed

0 to 100%

60

60

SWING XXX%

Displays/adjusts fixed swing speed

0 to 100%

60

60

BASKET LVL XXX%

Displays/adjusts fixed basket level
speed

0 to 100%

75

75

BASKET ROT XXX%

Displays/adjusts fixed basket rotate
speed

0 to 100%

75

75

MAIN TELE XXX%

Displays/adjusts fixed main telescope
speed

0 to 100%

60

60

TOWER TELE XXX%

Displays/adjusts fixed tower telescope
speed
Not displayed if TOWER TELE=NO

0 to 100%

100

100

T. LIFT UP XXX%

Displays/adjusts fixed tower lift up
speed
Not displayed if TOWER LIFT=NO

0 to 100%

100

100

T. LIFT DN XXX%

Displays/adjusts fixed tower lift down
speed
Not displayed if TOWER LIFT=NO

0 to 100%

100

100

JIB (U/D) XXX%

Displays/adjusts jib lift speed
Not displayed if JIB = 0

0 to 100%

60

60

JIB (L/R) XXX%

Displays/adjusts jib swing speed
Displayed if JIB = 2

0 to 100%

70

70

GEN SET/
WELDER:

ENGINE XXXX RPM

Control generator/welder RPM. Not dis-
played if GEN SET/WELDER = 0

1200-2800

1800

1800

4150453-F

Table 6-3. Personality Ranges/Defaults

SUBMENU

(DISPLAYED ON

ANALYZER 1ST

LINE)

PARAMETER

(DISPLAYED ON ANALYZER

2

ND

LINE)

DESCRIPTION

RANGE

DEFAULT VALUES

TIME RANGE (SEC)
(SEE SECTION 6.10

FOR MACHINE

ORIENTATION WHEN

SETTING SPEEDS)

1100S

1100SJP

1100S

11100SJP

Advertising