21 generator (sjp only), Every 250 hours, Every 500 hours – JLG 1100S Service Manual User Manual

Page 127: Generator (sjp only) -85, Every 250 hours -85 every 500 hours -85, Coupling port information table -85, 1/2 in. (13 mm)

Advertising
background image

SECTION 3 - CHASSIS & TURNTABLE

3121256

– JLG Lift –

3-85

3.21 GENERATOR (SJP ONLY)

Every 250 hours

Every 250 hours of operation, check the drive belt for
proper tension.

Every 500 hours

Every 500 hours of operation, service the generator
brushes and slip rings. Hostile environments may require
more frequent service.

Every 500 hours of service, blow out the inside of the gen-
erator. If operating in a hostile environment, clean
monthly.

Table 3-2. Coupling Port Information Table

Port

No.

Outlets

Port
Size

Description

Operating

Pressure
PSI (Bar)

Proof

Pressure
PSI (Bar)

1

2

-12

Steer/Axle Extend

(Tank)

250 (17)

375 (26)

2

2

-10

Steer/Axle Extend

(Pressure)

3000 (207) 4500 (310)

3

1

-10

Drive A

3000 (207) 4500 (310)

4

1

-10

Drive B

3000 (207) 4500 (310)

5

1

-10

Drive A

3000 (207) 4500 (310)

6

1

-10

Drive B

3000 (207) 4500 (310)

7

2

-12

Case Drain

250 (17)

375 (26)

1/2 in.

(13 mm)

Advertising
This manual is related to the following products: