SECTION 5 - HYDRAULICS

5-46

– JLG Lift –

3121256

3. Pumps clockwise driven must have a position of the

valve plate 4 degrees out of center in the same
direction decentered like drive direction.

4. Pumps counterclockwise driven must have a posi-

tion of the valve plate 4 degrees decentered in the
ccw position.

5. Note the correct position of the drilling that connects

high pressure to the control valve. Check control
valve drilling position at the pump housing and fit
together.

Adjustments

TAPER ROLLER BEARING INITIAL TENSION

Cast Iron pump housing must have initial tension of the
bearings: 0 to 0.05 mm.

MECHANICAL FLOW LIMITER

Differential volume if you are rotating the threaded pin -
each rotation is approximately 3.1 cm3.

Tightening Torques

For break-off plugs, use Loctite #601.
For all other parts, use Loctite #242.

Table 5-6. Tightening Torques

M4

M5

M6

M8 M10 M12 M14 M16 M18 M20 M24

M30

8.8

2.3

5.0

8.5

21

41

72

115

176

240

350

600

1220

10.9

3.2

7.2

12

29

58

100

165

250

350

490

840

1670

12.9

4.1

8.5

14.5

35

70

121

195

300

410

590

990

2000