Step 2: bleeding the platform valves, Step 2: bleeding the platform valves -55 – JLG 1100S Service Manual User Manual

Page 329

Advertising
background image

SECTION 6 - JLG CONTROL SYSTEM

3121256

– JLG Lift –

6-55

7. Use the arrow button to reach PERSONALITIES

adjust the following personalities. Refer to the Per-
sonality Ranges/Defaults table for proper setting val-
ues.

Basket Level Up Min
Basket Level Up Max
Basket Level Down Max
Jib Up Min
Jib Down Min

8. Recycle EMS.

STEP 2: BLEEDING THE PLATFORM VALVES

1. Position the Platform/Ground select switch to the

Ground position.

2. Plug the analyzer into the connector inside the

Ground control box.

3. Pull out the Emergency Stop switch and start the

engine.

4. The analyzer screen should read:

5. Use the arrow button to reach ACCESS LEVEL 2. Hit

Enter.

6. Enter the Access Code, 33271.

7. Go to the PERSONALITIES menu.

8. Using the left arrow button, go to the GROUND

MODE menu.

9. Hit ENTER.

10. Using the UP/DOWN arrows, adjust the following

personalities to 100%.

Basket Rotate
Basket Level
Jib U/D (if configured)

Start up the machine and exercise each above plat-
form function (from the ground) eight (8) to ten (10)
times for 5 seconds in each direction.

11. Return the personality settings back to the values as

shown in the Personality Ranges/Defaults table in
Section 6 - JLG Control System.

12. Recycle EMS.

Advertising