SECTION 6 - JLG CONTROL SYSTEM

6-56

– JLG Lift –

3121256

STEP 3: CALIBRATING THE PLATFORM
LEVEL UP AND DOWN VALVE CRACKPOINTS

1. Position the Platform/Ground select switch to the

Ground position.

2. Plug the analyzer into the connector inside the

Ground control box.

3. Pull out the Emergency Stop switch and start the

engine.

4. The analyzer screen should read:

5. Use the arrow button to reach ACCESS LEVEL 2. Hit

Enter.

6. Enter the Access Code, 33271.

7. Go to the CALIBRATIONS menu and hit ENTER.

8. Go to the BASKET U CRKPT Screen. Hit ENTER.

9. CALIBRATE? prompt should appear. Hit ENTER

again.

10. You will hear engine go to 1800 rpm.