19 calibrating the boom sensors, Calibrating the boom sensors -65, Boom sensor calibration position 1 -65 – JLG 1100S Service Manual User Manual

Page 339

Advertising
background image

SECTION 6 - JLG CONTROL SYSTEM

3121256

– JLG Lift –

6-65

6.19 CALIBRATING THE BOOM SENSORS

DURING THE BOOM SENSOR CALIBRATION PROCEDURE, IT IS
NORMAL FOR THE REAR WHEEL TO LIFT FROM THE GROUND
APPROXIMATELY 1 INCH (2.5 CM). IF THE WHEEL RAISES
APPRECIABLY MORE THAN THIS (I.E. 4 INCHES [10 CM] OR
MORE), CHECK THE AXLE OSCILLATION SYSTEM FOR PROPER
OPERATION OR THE NEED FOR BLEEDING, THEN PROCEED WITH
THE BOOM SENSOR CALIBRATION PROCEDURE.

Use the following step-by-step procedure to calibrate the
boom sensors.

1. Before the boom sensors can be calibrated, the fol-

lowing conditions must be met:

a. Steering, telescope crack points, and tilt previ-

ously calibrated

b. Axles Extended
c. Wheels Straight
d. Platform Unloaded
e. Jib Horizontal
f. Jib Swing Centered (1100SJP Only)
g. Platform Level
h. Platform Centered
i. Turntable Centered
j. Boom Fully Retracted
k. Level Ground (within 1.5°)

2. Position the Platform/Ground select switch to the

Ground position.

3. Plug the analyzer into the connector inside the

Ground control box.

4. Pull out the Emergency Stop switch and start the

engine.

Figure 6-14. Boom Sensor Calibration Position 1