JLG X500AJ Operator Manual User Manual

Page 132

Advertising
background image

SECTION 6 - GENERAL SPECIFICATIONS AND OPERATOR MAINTENANCE

6-22

– JLG Lift –

3121636

BYPASCB B

ON

The ground part safeties are disconnected through the key button (emergency

condition)– “B” line of the ground part safeties by-pass button is closed.

OFF

The ground part safeties are connected (normal working condition) – “B” line of the

ground part safeties by-pass button is opened

EM GRND A

ON

Emergency stop on the ground is released –“A” line of the emergency stop is

closed

OFF

Emergency stop on the ground is pressed – “A” line of the emergency stop is

opened

EM GRND B

ON

Emergency stop on the ground is released –“B” line of the emergency stop is

closed

OFF

Emergency stop on the ground is pressed – “B” line of the emergency stop is

opened

FOTO A

ON

Photocell A receives the signal from the reflector (Aerial part closed and aligned)

OFF

Photocell A does not receive the signal from the reflector (Aerial part opened)

FOTO B

ON

Photocell B receives the signal from the reflector (Aerial part closed and aligned)

OFF

Photocell B does not receive the signal from the reflector (Aerial part opened)

EM.R.C.GND

ON

The emergency stop on ground remote control is released.

OFF

The emergency stop on ground remote control is pressed or the ground remote

control is disconnected

Advertising