SECTION 6 - GENERAL SPECIFICATIONS AND OPERATOR MAINTENANCE

6-24

– JLG Lift –

3121636

p

p

p

TEMP ALRM B

Option reserved for some

markets

ON

The temperature external probe reached the maximum value – “B” line of the

temperature probe is closed

OFF

The temperature external probe hasn’t reached the maximum value – “B” line of the

temperature probe is open

POS.1 ARM

ON

The switch of 1-2 arm position is released, contact is close, the 1

st

-2

nd

arm is open

OFF

The switch of 1-2 arm position is pressed, contact is open, the 1

st

-2

nd

arm is closed

TRACK OPEN

ON

Tracks are in wide position. Widening cylinders switches are pressed, contact is

closed

OFF

Tracks are not in full wide position. Widening cylinders switches are released,

contact is open

FREE

Do not consider this signal

EMRG. COMM

ON

The control position key selector for aerial part operation from the ground is

activated (emergency condition)

OFF

The control position key selector for aerial part operation is released (normal

working condition)

MICROROPES

To consider only for

LL20JP - X600AJ

ON

The cables of the extension are OK. The control switch of the cables on extension is

released and the line is closed (normal working condition)

OFF

At list one cable on the extension is out of order. The control switch of the cables on

extension is pressed and the line is open (emergency condition)