Lithium-Ion Machine Fault Codes

(See “Errors Menu” on page 6-30 info for display information)

Table 6-10. Inverter Fault Codes

CODE

DESCRIPTION

1

Wrong Config
Cause - EEPROM memory not configured.
Solution - Contact Hinowa after.sales service.

8

Watch Dog
Cause - Inverter cannot start or stop electric motor.
Solution - Check connections and continuity of electric motor. If OK,
replace inverter.

13

Eeprom KO
Cause – EEPROM hardware or software problem.
Solution – Replace inverter.

16

Aux output KO
Cause – Problem with electromechanical brake.
Solution – This is generally a temporary problem due to certain working
conditions. If problem persists, replace inverter.

17

Logic failure #3
Cause – Activated in the event of high inverter current peaks.
Solution – This is generally a temporary problem due to certain working
conditions. If problem persists, replace inverter.

18

Logic Failure #2
Cause – Internal fault in the inverter.
Solution – Replace inverter.

19

Logic failure #1
Cause – Sudden voltage surge or voltage drop.
Solution – This is a temporary problem due to certain working condi-
tions. If problem persists, replace inverter.

30

VMN low
Cause – Inverter power supply voltage is lower than battery voltage, or
alternatively incorrect connection to positive battery pole.
Solution – Check connection to positive battery pole. If problem persists,
replace inverter.

31

VMN High
Cause – One motor phase not connected correctly or faulty.
Solution – Check motor phases. If problem persists, replace inverter.

37

Contactor closed
Cause – Relay remains closed when power to coil is disconnected.
Solution – Check relay.

38

Contactor Open
Cause – Inverter supplies power to relay coil but contact doesnft close.
Solution – Check relay and power supply to coil.

Table 6-10. Inverter Fault Codes