SECTION 4 - MACHINE OPERATION

4-4

– JLG Lift –

3121636

5. When finished operating with the electric engine,

turn off switch (item 1 - opposite side of machine),
unhook the electric AC cord from receptacle (item
2)
, and disconnect ground discharger cable (item
3)
, if it was required.

NOTE:

At low temperatures start the motor and let it run for a
few minutes, so that the hydraulic oil circulates and
reaches at least 50°F (10°C) before operating the plat-
form.

Electric Engine Starting Procedure - LITHIUM-ION
Machine

1. Set the ON/OFF switch on the lithium-ion battery

pack to the ON position, (0 symbol is OFF, 1 is ON).

2. The electric engine will auto start when a function

is activated at the platform or ground control sta-
tion.

3. Switch the ON/OFF switch on the lithium-ion bat-

tery pack to the OFF position when shutting down
at the end of a work period. (0 symbol is OFF, 1 is
ON)

2

3

1