SECTION 6 - GENERAL SPECIFICATIONS AND OPERATOR MAINTENANCE

3121636

– JLG Lift –

6-23

PROXIMITY

ON

Turret is not almost completely rotated, contact is close, the 1

st

-2

nd

arm is not

above the engine

OFF

Turret is almost completely ro tated, contact is open, the 1

st

-2

nd

arm is above the

engine

EM.R.C.GND

ON

The stop button on ground remote control is released.

OFF

The stop button on ground remote control is pressed or the ground remote

control is disconnected

ST12 CLOSED

ON

The pressure switch of outriggers 1 and 2 closes the contact – the outriggers are at
end run and the max pressure valve is opened

OFF

The pressure switch contact of outriggers 1 and 2 is opened – the outriggers are

open, partially open or already closed

ST34 CLOSED

ON

The pressure switch of outriggers 3 and 4 closes the contact – the outriggers are at

end run and the max pressure valve is opened

OFF

The pressure switch contact of outriggers 3 and 4 is opened – the outriggers are

open, partially open or already closed

TEMP ALRM A

Option reserved for some

markets

ON

The temperature external probe reached the maximum value – “A” line of the

temperature probe is closed

OFF

The temperature external probe hasn’t reached the maximum value – “A” line of the

temperature probe is open

Advertising