Table 4-1. Battery Charger Fault Codes

FLASH(s)

FAULT

MODE(S) AFFECTED

REMEDY

1

High battery voltage

Invert or Charge

Discharge battery, unit will auto start.

2

Low battery voltage

Invert or Charge

Connect qualified external AC to charge batteries.

3

Charge time is greater than 20 hrs.

Charge

Remove DC loads or replace batteries.

4

Shorted battery

Charge

Replace Battery.

5

Over-temperature

Invert

Turn the toggle switch to Standby and allow inverter/charger to cool.

6

Over load

Over current

Invert or Charge

Remove excessive AC loads and reset unit by turning the toggle switch to Standby
they ON.