6-7 Accessory

DTC

FAULT MESSAGE

DESCRIPTION

CHECK

671

ACCESSORY FAULT

An accessory module is reporting a fault.

See accessory module documentation for troubleshooting.

Refer problem to a qualified JLG mechanic.

7-7 Electric Motor

DTC

FAULT MESSAGE

DESCRIPTION

CHECK

771

OPEN CIRCUIT DRIVE MOTOR WIRING

The power module detected a problem in
the drive motors' power circuit wiring.

Refer problem to a qualified JLG mechanic.

772

STALLED TRACTION MOTOR OR POWER
WIRING ERROR

The power module detected a problem in
the drive motors' power circuit wiring.

Refer problem to a qualified JLG mechanic.

773

CAPACITOR BANK FAULT - CHECK
POWER CIRCUITS

The power module detected a problem in
the pump or drive motors' power circuit wir-
ing.

Refer problem to a qualified JLG mechanic.

774

SHORT CIRCUIT FIELD WIRING

The power module detected a problem in
the drive motors' power circuit wiring.

Refer problem to a qualified JLG mechanic.

775

OPEN CIRCUIT FIELD WIRING

The power module detected a problem in
the drive motors' power circuit wiring.

Refer problem to a qualified JLG mechanic.

776

STALLED PUMP MOTOR OR POWER
WIRING ERROR

The power module detected a problem in
the drive motors' power circuit wiring.

Refer problem to a qualified JLG mechanic.