4-2 Thermal Limit (SOA)

DTC

FAULT MESSAGE

DESCRIPTION

CHECK

421

POWER MODULE TOO HOT - PLEASE
WAIT

The power module has reached thermal cut-
out.

Power down and allow to cool.
Do not operate in ambients over 140° F (60° C).

Refer problem to a qualified JLG mechanic.

422

DRIVING AT CUTBACK - POWER MOD-
ULE CURRENT LIMIT

The drive portion of the power module has
reached thermal limit.

Refer problem to a qualified JLG mechanic.

423

LIFT UP AT CUTBACK - POWER MODULE
CURRENT LIMIT

The lift up portion of the power module has
reached thermal limit.

Refer problem to a qualified JLG mechanic.

4-4 Battery Supply

DTC

FAULT MESSAGE

DESCRIPTION

CHECK

441

BATTERY VOLTAGE TOO LOW - SYSTEM
SHUTDOWN

A problem has been detected with the bat-
teries or power module.

Recharge batteries or check for damaged batteries.
Check battery charger function.

Refer problem to a qualified JLG mechanic.

442

BATTERY VOLTAGE TOO HIGH - SYSTEM
SHUTDOWN

A problem has been detected with the bat-
teries or power module.

May be due to improper battery charging or incorrect voltage batteries

being used.

Refer problem to a qualified JLG mechanic.

443

LSS BATTERY VOLTAGE TOO HIGH

A problem has been detected with the load
sense system.

May be due to improper battery charging or incorrect voltage batteries

being used.

Refer problem to a qualified JLG mechanic.