SECTION 6 - GENERAL SPECIFICATIONS AND OPERATOR MAINTENANCE

3121221

– JLG Lift –

6-13

005

DRIVE & LIFT UP PREVENTED - TILTED &
ELEVATED

Driving is not possible since the platform is
elevated and the chassis is not level.

• Check that the machine is tilted. If so, lower the platform and reposition

the machine to a level surface.

• Fully stow the platform.
• The tilt sensor is part of the ground control box. Check that the ground

control box is secured to the machine.

• Check that the pothole protection switches are securely mounted.
• Check that the elevation angle sensor is securely mounted.

Refer problem to a qualified JLG mechanic.

006

LIFT UP PREVENTED - MAX HEIGHT
ZONE A

The vehicle has reached the maximum
height and further lift up motion is not pos-
sible. Applicable to 2630ES or 3246ES.

• Check that the zone is set appropriately for the platform load.
• Check that the platform height is at the rated maximum height specifica-

tion (20’ for 2630 or 26’ for the 3246).

• Check that the elevation angle sensor is securely mounted.
• If there are any elevation sensor faults (DTC 251, 252, 2511, or 2512),

troubleshoot those first.

Refer problem to a qualified JLG mechanic.

007

DRIVING AT CUTBACK - POTHOLE STILL
ENGAGED

While stowed, drive speed is reduced since
the control system detected that the pot-
hole protection mechanism failed to retract.

• Check for obstructions around the pot-hole protection mechanisms.
• Check that the PHP switches are securely mounted.

Refer problem to a qualified JLG mechanic.

008

FUNCTIONS LOCKED OUT - SYSTEM
POWERED DOWN

After 2 hours without activity, the control
system enters a low-power state to preserve
battery charge.

• Normal operation should resume after power is cycled off then back on.
• Check batteries charge, condition, etc.

Refer problem to a qualified JLG mechanic.