DRIVE PREVENTED - ELEVATED ABOVE
DRIVE CUTOUT HEIGHT

The platform is elevated above the cali-
brated cutout height.

Check that the elevation angle sensor is securely mounted.

Refer problem to a qualified JLG mechanic.

0-0 Help Comments

DTC

FAULT MESSAGE

DESCRIPTION

CHECK

2-1 Power-Up

DTC

FAULT MESSAGE

DESCRIPTION

CHECK

211

POWER CYCLE

This help message is issued at each power
cycle. Displays on the analyzer only.

Normal operation. No check necessary.

212

KEYSWITCH FAULTY

Both platform and ground modes are
selected simultaneously. Defaults to
ground mode.

Refer problem to a qualified JLG mechanic.

2-2 Platform Controls

DTC

FAULT MESSAGE

DESCRIPTION

CHECK

221

FUNCTION PROBLEM - HORN PERMA-
NENTLY SELECTED

The horn switch was closed during power-
up in platform mode.

Check if the horn switch is damaged, obstructed or jammed.

Refer problem to a qualified JLG mechanic.

222

FUNCTION PROBLEM - INDOOR / OUT-
DOOR PERMANENTLY SELECTED

The indoor / outdoor (zone A / zone B)
switch was closed during power-up in plat-
form mode.

Check if the indoor/outdoor (zone A / zone B) capacity switch is damaged,

obstructed or jammed.

Refer problem to a qualified JLG mechanic.