3 ground controls, 5 function prevented, 3 ground controls -16 2-5 function prevented -16 – JLG 1230ES Operator Manual User Manual

Page 80

Advertising
background image

SECTION 6 - GENERAL SPECIFICATIONS AND OPERATOR MAINTENANCE

6-16

– JLG Lift –

3121221

2-3 Ground Controls

DTC

FAULT MESSAGE

DESCRIPTION

CHECK

231

FUNCTION PROBLEM - LIFT PERMA-
NENTLY SELECTED

The ground control box lift switch was
closed up or down, during power-up in
ground mode.

Check if the lift switch is obstructed or jammed.

Refer problem to a qualified JLG mechanic.

232

GROUND LIFT UP / DOWN ACTIVE
TOGETHER

The lift up / down inputs are closed simulta-
neously.

Check if the lift switch is obstructed or jammed.

Refer problem to a qualified JLG mechanic.

233

FUNCTION PROBLEM - BRAKE RELEASE
PERMANENTLY SELECTED

The manual brake release switch was closed
during power-up.

Check if the brake release switch is obstructed or jammed.

Refer problem to a qualified JLG mechanic.

2-5 Function Prevented

DTC

FAULT MESSAGE

DESCRIPTION

CHECK

251

ELEV ANGLE SENSOR FAULTY - VOLTAGE
OUT OF RANGE

There is a problem with the elevation angle
sensor input.

Check that the platform elevation sensor is securely mounted and

undamaged.

Refer problem to a qualified JLG mechanic.

252

ELEV ANGLE SENSOR HAS NOT BEEN
CALIBRATED

The elevation angle sensor has not been cal-
ibrated.

Refer problem to a qualified JLG mechanic.

253

DRIVE PREVENTED - CHARGER CON-
NECTED

Driving is not possible while the vehicle is
charging.

Check if the charger is connected to off board power source and discon-

nect if desired.

Refer problem to a qualified JLG mechanic.

Advertising