444

LSS BATTERY VOLTAGE TOO LOW

A problem has been detected with the load
sense system.

• Recharge batteries or check for damaged batteries.

Refer problem to a qualified JLG mechanic.

446

4421
4422

LOGIC SUPPLY VOLTAGE OUT OF RANGE The System Module logic supply voltage

was measured to be out of normal operating
range.

• Check for severely discharged battery, loose cables or for damaged bat-

tery; otherwise;

• Refer problem to a qualified JLG mechanic.

4-4 Battery Supply

DTC

FAULT MESSAGE

DESCRIPTION

CHECK

6-6 Communication

DTC

FAULT MESSAGE

DESCRIPTION

CHECK

661

CANBUS FAILURE - POWER MODULE

The control system failed to receive mes-
sages from the power module.

Refer problem to a qualified JLG mechanic.

662

CANBUS FAILURE - PLATFORM MODULE In platform mode, the control system failed

to receive messages from the platform
board.

Refer problem to a qualified JLG mechanic.

663

CANBUS FAILURE - LOAD SENSING SYS-
TEM MODULE

With load sensing system enabled, the con-
trol system failed to receive messages from
the load sensing system module.

Refer problem to a qualified JLG mechanic.

664

CANBUS FAILURE - ACCESSORY MOD-
ULE

An accessory module has stopped commu-
nication.

• See accessory module documentation for troubleshooting.

Refer problem to a qualified JLG mechanic.

6635 CANBUS FAILURE - CHASSIS TILT SEN-

SOR

Machine control system lost communica-
tion with the machines’ tilt sensor.

• Refer problem to a qualified JLG mechanic.