SECTION 4 - BOOM & PLATFORM

3121160

– JLG Lift –

4-45

4.15 FOOT SWITCH ADJUSTMENT

Adjust so that functions will operate when pedal is at cen-
ter of travel. If switch operates within last 1/4 in. (6.35 mm)
of travel, top or bottom, it should be adjusted.

4.16 UPRIGHT MONITORING SYSTEM

The UMS provides a visual and audible warning to the
operator when the limits of the upright assembly align-
ment have been reached. In addition, the UMS will not
allow the tower boom to be lowered when the upright
assembly is misaligned in a direction oriented away from
the work platform.

Re-Synchronizing Upright

A pull type control valve allows the operator to adjust the
upright level cylinder if the upright is not 90° (vertical) rela-
tive to the chassis (Refer to Figure 4-20.). This valve is
located in the tank compartment area.

Perform the following steps with the aid of an assistant:

1. Turn the key switch to the ground control position.

2. Start the engine.

3. Pull and hold the red relevel knob located next to the

main control valve. Refer to Figure 4-19.

4. Raise the tower boom 6 feet (1.8 m).

5. Release the red relevel knob.

6. Lower the tower boom fully and continue to hold

down the switch to Tower Down for an additional 20
seconds.

7. Repeat steps 3 thru 6 as necessary until the upright

is 90° (vertical) relative to the chassis.

Table 4-2. Ramp Current Setting Range.

FUNCTION

MINIMUM

CURRENT

MAXIMUM
CURRENT

MAIN LIFT UP

450 to 550 mA

‘1300 to 1500 mA

MAIN LIFT DOWN

450 to 550 mA

1700 to 2000 mA

(Set 450 mA higher

than Main lift)

SWING RIGHT

450 to 550 mA

1000 to 1300 mA

SWING LEFT

450 to 550 mA

1100 to 1300 mA

(Set 100 mA higher

than swing right)

FLOW CONTROL

750 to 850 mA

1100 to 1300MA
(Set using Main Tele)

DRIVE FORWARD

20 to 60 mA

130 to 160 mA

DRIVE REVERSE

20 to 60 mA

130 to 160 mA

Table 4-3. Ramp time Setting.

FUNCTION

RAMP TIME

Lift Up

Ramp UpTime = 5:00 sec.
Ramp Down Time = 3:00 sec.

Lift Down

Ramp Up Time =5:00 sec.
Ramp Down Time =3:00 sec.

Swing Right

Ramp Up Time =7:00 sec.
Ramp Down Time =3:00 sec.

Swing Left

Ramp Up Time =7:00 sec.
Ramp Down Time =3:00 sec.

Drive Forward

Ramp Up Time =4:30 sec.
Ramp Down Time = 2:30 sec.

Drive Reverse

Ramp Up Time = 4:30 sec.
Ramp Down Time = 2:00 sec.

Flow Control

Ramp Up Time =3:00 sec.
Ramp Down Time =0.00 sec.

Figure 4-18. Control Card