SECTION 4 - BOOM & PLATFORM

3121160

– JLG Lift –

4-59

7. Enter the service code "81075" and press the

"ENTER"

key. The controller display will now

display the following,

followed by:

The flashing and scrolling messages will repeat until

the "ENTER"

key is pressed.

8. When the "ENTER"

key is pressed, the UMS

will be disabled and the display will read:

9. Before using tower lift down adhere to the following:

• Make sure the main boom is fully retracted.
• Make sure the tower boom is fully retracted.
• Slowly lower the tower boom.

10. When the platform has been safely lowered to the

ground, exit the service mode by pressing the Emer-
gency Stop Switch (EMS) at the ground controls.
Upon loss of power (pressing the EMS) to the sys-
tem, the upright monitoring system will reset and all
functionality will be restored to the machine.