SECTION 1 - SPECIFICATIONS

1-10

– JLG Lift –

3121160

7.Suction Strainers

Lube Point(s) - 2
Interval - Every 2 years or 1200 hours of operation,
remove and clean at time of hydraulic oil change.

8.Oil Change w/Filter - Ford

Lube Point(s) - Fill Cap/Spin-on Element
Capacity - 4.5 Quarts
Lube - EO
Interval - 3 Months or 150 hours of operation
Comments - Check level daily/Change in accor-
dance with engine manual.

9.Oil Change w/Filter - Deutz

Lube Point(s) - Fill Cap/Spin-on Element
Capacity - 11 Quarts(10.5 L) Crankcase
Lube - EO
Interval - Every Year or 1200 hours of operation
Comments - Check level daily/Change in accor-
dance with engine manual. Refer to Figure 1-2.,
Deutz Engine Dipstick.

MINIMUM LEVEL,
OIL HOT

MINIMUM OIL
LEVEL

MINIMUM LEVEL,
OIL COLD

NOTE: Hot oil checks should not be made until the engine
has been shut down for a period of 5 minutes.

MAXIMUM LEVEL,
OIL HOT

MAXIMUM LEVEL,

OIL COLD

MAXIMUM OIL
LEVEL

Figure 1-2. Deutz Engine Dipstick

Advertising