SECTION 4 - BOOM & PLATFORM

4-68

– JLG Lift –

3121160

Shown below is the slip indicator with a gap, signifying
that the fall arrest system should be replaced immediately.

Annual Inspection and Certification

THE EXTERNAL FALL ARREST SYSTEM REQUIRES AN ANNUAL
INSPECTION AND CERTIFICATION. THE ANNUAL INSPECTION
AND CERTIFICATION MUST BE PERFORMED BY A COMPETENT
PERSON.

If inspection services are required, contact:

Flexible Lifeline Systems
14325 West Hardy Rd.
Houston, TX 77060
Phone: 281-448-8821

The following items should be checked per your mainte-
nance schedule.

Cable:

Corrosion
Broken Strands
Swage Pull Out
Dust or Debris

Fittings:

Loose Fittings
Hardware (Nuts and Bolts)
Hanger
Corner Bracket
Line Tenser/Transfastener

Installation

Installation requires bolting the ends of the cable to the
platform with the supplied drilled bolt, castle nut, and split
pin. The drilled bolts only need to be tightened enough to
fully engage all of the threads of the castle nut and then
further just enough to install the split pin. The intermediate
supports are also bolted to the platform. The intermediate
supports are adjusted to an angle slightly below horizontal
to improve the movement of the transfastener. Ensure all
bolts and locknuts are tightened properly. The cable is
then tensioned until the tension indicator spins and the
locking pins are then installed in the turnbuckle to hold it
in place.