SECTION 4 - BOOM & PLATFORM

4-66

– JLG Lift –

3121160

Out of Usable Range Message

8/1 UMS SENSOR OUT OF USABLE RANGE

When both the Chassis tilt sensor and the UMS sensor
read greater than 10 in the same direction the UMS will
be disengaged until the condition no longer exists and a
fault shall be raised.

Solution:

• Verify the message clears when operating the machine

on grade less than 10.

• Inspect sensor mounting.
• Verify sensor calibration on level pad.

UMS Sensor Not Calibrated Message

8/1 UMS SENSOR NOT CALIBRATED

If the control system detects a sensor out of range condi-
tion or a not calibrated fault with the UMS angle sensor,
the control system shall report a fault and disable Tower
Lift Down and activate the ground boom malfunction indi-
cator lamp, upright tilted lamp and platform alarm continu-
ally

If the control system detects that the UMS angle sensor
has not been calibrated, the ground boom malfunction
lamp will flash at a 3 Hz rate until the system is calibrated
or disabled.

Solution:

• Calibrate sensor.

UMS Sensor Faulted Message

8/1 UMS SENSOR FAULTED

If the system detects that the UMS sensor frequency out-
side the 100Hz +/- 5Hz range or the duty cycle is outside
50% +/- 21% range the control system shall report a fault.

Solution:

• Inspect wire harness going to the sensor and UMS

module.

• Inspect sensor mounting.
• Replace sensor.

Incompatible Software Detected Message

9/9 INCOMPATIBLE SOFTWARE DETECTED

If the control system detects that the ground module soft-
ware is incompatible with the UMS module, the UMS mod-
ule shall report a fault and disable the footswitch signal to
the ground module.

Solution:

• Update ground module software.

Calibration Faults

CAL FAILED-CHASSIS NOT LEVEL

The control system shall display a fault in the event the
raw sensor output is greater than 5° for the chassis sen-
sor.

CAL FAILED-UMS SENSOR RAW OUTPUT OUT OF
RANGE

The control system shall display a fault in the event the
raw sensor output is greater then 5° for the UMS sensor.

CAL FAILED-CALIBRATION DISRUPTED

If calibration is disrupted, the control system shall display
this fault.

C A L FA I L E D - U M S S E N S O R M OV E M E N T N O T
DETECTED

The UMS angle has not detected the required amount of
movement during calibration.