Free minutes bank, Table of parameters 3.2 – 2N Analogue GSM gateway 2N EasyGate PRO - Manual, 1749 v1.03 User Manual

Page 39

Advertising
background image

Table of Parameters

3.2

39

for example received CLI +420603198222 corresponds with settings:

CLI - calling number

Substring

+420603198222

any setting

+420603

any setting

+420

any setting

603198222

4, or more

603

4, or more

Setting options:

0-15

Step:

1

Default setting:

0

Route to

Function No.: 591

It is possible to route incoming call from mobile network to FXS interface or

reject it. When the call is routed to FXS port you can use the CallBack feature.

For correct functionality please set up "Max. ring time for Callback" parameter.

Setting options:

FXS (0) -incoming call is routed to FXS

FXS CallBack (2) -incoming call is routed to FXS with

CallBack functionality

Reject (4) -incoming call is rejected

Default setting:

FXS

Dial in

Function No.: 592

Parameter "Dial in" is used for automatic connection to switchboard operator, or

directly to other subscriber. If this parameter is blank, calling person has

telephone line fully at disposal and has to dial the subscriber number by DTMF.

You can fill only # character to disable Dial in function.

Setting options:

0-16 characters (0-9,*,#)

Default setting:

blank

Time limit [min]

Function No.: 599

After time elapsing is call connection terminated immediately. You can hear beep

30s before end of call. 10s before end you can hear beep every second. The "0"

setting means that the function is disabled.

Setting options:

0-255 min

Setting step:

1 min

Default setting:

0 min