Free minutes option

4.6

61

4.6 Free minutes option

Basic description

With Firmware 3.5x only!
Free minutes option allows user to control amount of minutes used for four groups of

operators in one month period. The user than knows, if performed calls are included in

free minutes bundle, or if he has to pay extra price for it. Calls for extra price can be

disabled. All setting done by customer is accessible by DTMF setting.
Setting of prefixes (operators) in four banks can be changed using PCManager. This

setting, the amount of free minutes in every bank and rules for time counting are

preset from factory.

Programming of parameters is done the same way like programming of all other

gateway parameters. To change free minutes option parameters, you can either:

· Use the DTMF programming on a telephone line. There are parameters, which

can be programmed using telephone line based programming with password

access as described in part 3.1 and commands with direct access, used the

same way as command for configuration of network services as described in

part 4.1.

· Use a PC with the PCManager installed.

Parameters – password access

Call with empty bank permitted

Function No.: 310

The call with empty Bank is either disabled or permitted. When the bank is

empty, you hear after dial refusing tone. With call disabled is followed by

Busy tone and the call can’t be established. With call permitted you can

hang up the call, otherwise the call is established and charged.
Setting options: 0/1 (disabled / permitted)
Default setting: 0

Date for automatic refill

Function No.: 311

The day in month, when all four banks of free minutes will be refilled with

predefined values. The refilling is done in time 00:00:01 of selected day.

When the date for refill doesn't exist (31.2.), the refill is done first day after

this date (1.3.).
Setting options: 0-31 (0 – function off)
Default setting: 0

Next automatic refill – information field

Minutes available till the end of billing period.