Table of Parameters

3.2

44

Telephone number for service SMS

Function No.: 714

Telephone number for service SMS. The number is common for GGMC SMS and

"LOW CREDIT" SMS on prepaid SIM cards.

Setting options:

0-16 characters (0-9,*,#,+)

Default setting:

blank

Time period for GGMC SMS [h]

Function No.: 970

Time interval for GGMC SMS sending. GGMC = GSM Gateway Monitoring Centre.

The "0" setting means that the function is disabled.

Setting options:

0-255 h

Step:

1 h

Default setting:

0

Battery status SMS

Function No.: 962

Setting of this parameter allows sending SMS with information with battery status.

Disconnecting of battery (Battery Error) and connecting of battery (Battery Ready)

and critically low voltage (Battery flat) is reported by SMS.

Setting options:

enable (1)

disable (0)

Default setting:

disable

Power failure SMS

Function No.: 963

Mains status can be reported when this parameter is set. The report about mains

failure and recover is sent with defined delay (Power off/on).

Setting options:

disable (0)

Enable with delay 1-255 min

Default setting:

disable

Initialization

All programmable parameters are arranged in tables according to their functions. You

can initialize either all parameters at once or one table of parameters.

Telephone line initialization FXS

Function No.: -

Initialization of all parameters necessary for the telephone line FXS.

Call table initialization FXS

Function No.: -

Initialization of all parameters related to FXS routing table.

Call table initialization GSM

Function No.: -

Initialization of all parameters related to the routing table from mobile network.