2N TELEKOMUNIKACE a.s., www.2n.cz

®

Monitoring

This section helps you configure sending of SNMP traps. Download the list of available
traps, i.e. the MIB table, from the gateway web interface. The main purpose of SNMP
monitoring is to observe your GSM gateway states continuously and send state
information to the defined IP addresses whenever an error occurs.

Refer to the

for the list of all SNMP traps sent by

.

List of SNMP traps

2N BRI

®

Common Settings

General

– define the maximum/minimum level of the signal received by the

Signal level
GSM/UMTS module. The SNMP trap is sent automatically whenever the defined
values are exceeded.

– define the maximum filling capacity of the SMS

SMS bufer upper limit
storage. The SNMP trap is sent automatically whenever the defined value is
exceeded.

SNMP

General

– enable/disable the SNMP service.

Enabled

– SNMP community is a group that owns the device and control

Community
stations on which SNMP is running. Default value = public.

Caution

This service is subject to licence! Refer to Management / Licence key
for the current GSM gateway licence state details.

Tip

You can also apply ISDN monitoring to monitor the ISDN PRI line state.
Refer to

for

Gateway Configuration / ISDN Parameters – Monitoring

details.