9. Service Mode

9.7.1

Start Up of the Serial Communication

Start up

1. Push the cursor key ↑ or ↓ to highlight Serial communication.

SERVICE

IDENTIFICATION

CHANGE PASSWORD
CHANGE LANGUAGE

CHANGE PROJ. ADDRESS

SERIAL COMMUNICATION

NETWORK

LAMP

DIMMING
MORE...

Select with

or

then <ENTER>

<EXIT> to return

Menu 9-17

2. Press ENTER to display the Serial Communication menu.

SERIAL COMMUNICATION

PROJECTOR ADDRESS 001

BAUDRATE [115200]

INTERFACE STANDARD [RS232]

RS422 TERMINATION [ON]

Select with

or

then <ENTER>

<EXIT> to return

Menu 9-18

9.7.2

Baud rate Setting

Set up

To change the baud rate, handle as follow:
1. Push the cursor key ↑ or ↓ to highlight Baudrate.

SERIAL COMMUNICATION

PROJECTOR ADDRESS 001

BAUDRATE [115200]

INTERFACE STANDARD [RS232]

RS422 TERMINATION [ON]

Select with

or

then <ENTER>

<EXIT> to return

Menu 9-19

The actual baud rate will be displayed.

2. Press ENTER to toggle between the available baudrates.

Default : 9600

Available baud rates.

115200/57600/38400/19200/9600/4800/1200

116

R5976654 SLM R12+ 27/01/2005