3. Installation Guidelines

Image 3-19
Mounted Lens

Caution:

On a table mounted projector, hold the projector when pushing the lens into the lens block to avoid sliding off from
the table.

3.7.5

Cleaning the lens

To minimize the possibility of damaging the optical coating or scratching exposed lens surface, we have de-
veloped recommendations for cleaning the lens. FIRST, we recommend you try to remove any material from
the lens by blowing it off with clean, dry deionized air. DO NOT use any liquid to clean the lenses.

Necessary tools

Toraysee

TM

cloth (delivered together with the lens kit). Order number : R379058.

How to clean the lens ?

Proceed as follow :
1. Always wipe lenses with a CLEAN Toraysee

TM

cloth.

2. Always wipe lenses in a single direction.

Warning:

Do not wipe back and forwards across the lens surface as this tends to grind dirt into the coating.

3. Do not leave cleaning cloth in either an open room or lab coat pocket, as doing so can contaminate the cloth.

4. If smears occur when cleaning lenses, replace the cloth. Smears are the first indication of a dirty cloth.

W

ARNING

:

Do not use fabric softener when washing the cleaning cloth or softener sheets when drying the

cloth.

Do not use liquid cleaners on the cloth as doing so will contaminate the cloth.

C

AUTION

:

Other lenses can also be cleaned safely with this Toraysee

TM

cloth.

3.8 Battery Installation in the RCU

How is the battery delivered ?

The battery for the RCU is not yet installed on delivery, to save the battery life time, and is placed in the upper compartment (B)
inside the RCU (image 3-20).

How to plug in!

1. Press the battery cover (A) lock (1) inwards and simultaneously lift up the cover (2) for removal.

R5976654 SLM R12+ 27/01/2005