9. Service Mode

The lamp menu will be displayed.

LAMP

Constant Light output [OFF]

Using [RS port]

Mode [NORMAL]

Serial number :

R101111

Article number :

R9840xxx

Run time :

10 hours

Remaining run time :

490

hours

Number of strikes :

10

Z_AXIS : 100

Select with

or

then <ENTER>

<EXIT> to return.

Menu 9-27

How to switch the constant light output?

1. Push the cursor key ↑ or ↓ to highlight Constant Light Output.menu 9-27

2. Press ENTER to toggle between [OFF], [SLAVE] and [MASTER].

[OFF]

fixed power, no power adaptation.

[SLAVE]

follows the master projector to adjust the CLO. When stand alone and the light output should be adjusted,
put on slave.

[MAS-
TER]

master projector to control the CLO in a chain of projectors.

Linked port

1. Push the cursor key ↑ or ↓ to highlight Using.menu 9-27

2. Press ENTER to toggle between [RS port] or [Comm port].

[RS port]

RS port is used to make a linked connection

[Comm port]

Comm port is used to make a linked connection

Mode switching

1. Push the cursor key ↑ or ↓ to highlight Mode.menu 9-27

2. Press ENTER to toggle between [NORMAL] and [ECONOMIC].

normal

normal light output

economic

reduced light output (+ less noise)

9.10 Dimming

What is possible

The lamp can be dimmed in small steps only when the lamp is used in Normal mode. The dimming can be done between normal
mode and economic mode.

How to dim

1. Push the cursor key ↑ or ↓ to highlight Dimming.