7. Random Access Adjustment Mode

2. Press ENTER to select.

3. Push the cursor key ↑ or ↓ to highlight Status.

SCENERGIX

STATUS [ON]

- size -

TOP

BOTTOM

LEFT

RIGHT

- black level -

LEVEL

Select with

or

then <ENTER>

<EXIT> to return

Menu 7-50

4. Press ENTER to toggle between ON and OFF.

ON

scenergix is active

OFF

scenergix is not active

7.5.5

ScenergiX overlap zone (horizontal scenergix)

Definitions

Image 7-10
Scenergix set up

Overlap : number of pixels that overlap

Horizontal resolution of 1 projector : 1024 for Graphics versions, 1280 for Reality versions, 1400 for SXGA projectors.

Total horizontal screen resolution : [(horizontal resolution of 1 projector) x 2] minus overlap.

Horizontal Resolution source : number of active pixels of the source.

Adjustment of Active pixels (Pact) of the first projector

1. Go to File –> Edit menu of first projector.

2. Enter value for horizontal active (= Pact) as follows :

Pact = [(Horz. resolution of 1 projector)/(Total horz. screen resolution)] x (horz. resolution source)

3. Horizontal start (= Pstart) remains the same.

Adjustment of Active pixels (Pact) of second projector

1. Go to File –> Edit menu of second projector.

2. Enter value for horizontal active (= Pact) as follows :

Pact = [(Horz. resolution of 1 projector)/(Total horz. screen resolution)] x (horz. resolution source)

3. Horizontal start (= Pstart) = original start + [(Horz. resolution source) minus (newly calculated Pact)]

86