3. Installation Guidelines

A

Image 3-16
Lamp Z-Axis alignment (Former lamp house)

B

A

Image 3-17
Lamp Z-Axis alignment (Universal lamp house)

6. Slowly turn the screw B (image 3-16, , image 3-17, using an Allen key of 3 mm, a little clockwise until the maximum value of the

Z-AXIS indication in the lamp menu is reached.

7. Tighten the lock nut on the adjustable screw to secure its position (nutdriver 10).

C

AUTION

:

Never turn the other screws ! These are factory aligned.

22

R5976654 SLM R12+ 27/01/2005