Service mode – Barco SLM R12+ User Manual

Page 124

Advertising
background image

9. Service Mode

100

Clo value

Time [h]

Li

g

ht

ou

tp

ut

[%

]

Image 9-6

Linking via the RS232 in/out

The constant light output of projectors in a chain (maximum 12 projectors) can be set to the same value by linking the projectors via
the RS232 connector.

To the RS232in of the first projector, a terminator must be connected (Z3498823). The out of the first must be connected to the in
of the next projector, etc.

All projectors must have a different projector address between 1 and 12.

All must have the same baud rate and RS mode.

The constant light output setting of one projector must be in the master position. All others must be in the slave position.

Proj 1

Proj 2

Proj 3

Proj 4

in

in

in

in

out

out

out

RS

RS

RS

Terminator

Image 9-7
Principal diagram : linking via RS port

Linking via the Comm port

The constant light output of the projectors can be set to the same value by linking the projectors via the Comm port and using one
or more Comm 800 splitters (See Connections, Linked System).

120

R5976654 SLM R12+ 27/01/2005