6 communication connections, 1 rs232 (rs422) connection, 2 linked system – Barco SLM R12+ User Manual

Page 46: Communication connections, Rs232 (rs422) connection, Linked system, Connections, Overview, 2 linked system c, What can be done

Advertising
background image

4. Connections

6. Push the cursor key ↑ or ↓ to select the third or fourth slot.

INPUT SLOTS

Slot Module type [config]
1.

RGB-SS [CV]

2.

RGB-SOG

3.

SDI

4.

SDI

______________
1. DVI OUTPUT [DVI input]

Select with

or

then <ENTER>

<EXIT> to return

Menu 4-9

7. Press ENTER to toggle.

Possible indications on the input slot menu.
- VIDEO[VDEO]
- VIDEO[S-VIDEO]
- VIDEO[YUV]

4.6 Communication Connections

Overview

RS232 (RS422) Connection

Linked System

Communication with peripherals

Network connection

4.6.1

RS232 (RS422) Connection

Application

1.

Remote control :
- easy adjustment of projector via an IBM PC (or compatible) or MAC connection.
- allow storage of multiple projector configurations and set ups.
- wide range of control possibilities.
- address range from 0 to 255.

2.

data communications : sending data to the projector or copying the data from the projector to a hard memory device (hard disc,
floppy, etc.).

Set up of the Baud Rate for communication with a computer.

see "Baud rate Setting", page 116.

4.6.2

Linked System

C

AUTION

:

Always use the Barco COM 800 Splitter, R9827941 (240V) or R9827948 (110V), when using the COM

800 protocol.

What can be done?

In a complex multi-channel setup, projectors can be controlled using the RS232 or COM800 Protocol.

CLO can be controlled by both protocols, however by using the COM800 port for this adjustment, the RS232 Port can still be used
for general RS232 commands.

The following procedure will describe how to connect COM800 Linked System.

How to connect a COM800 Setup

Always use the Barco COM 800 Splitter, R9827941 (240V) or R9827948 (110V), when using the COM 800 protocol.
1. Use a data cable with at least 9 cores and 2 DB9 female connectors, just cross the pin 2 and pin 3 connection to make a Custom

Null Modem Cable.

42

R5976654 SLM R12+ 27/01/2005