3. Installation Guidelines

Image 3-15
Lamp adjustment access

3. Start up the adjustment mode and select Service.

ADJUSTMENT MODE

Select a path from below :

RANDOM ACCESS

INSTALLATION

SERVICE

Select with

or

then <ENTER>

<EXIT> to return

Menu 3-2

4. Select Lamp. The Z-axis value indication (lamp menu in service mode) will be helpful while turning screw B .

SERVICE

IDENTIFICATION

CHANGE PASSWORD
CHANGE LANGUAGE

CHANGE PROJ. ADDRESS
SERIAL COMMUNICATION

NETWORK

LAMP

DIMMING
MORE...

Select with

or

then <ENTER>

<EXIT> to return

Menu 3-3

LAMP

Constant Light output [OFF]

Using [RS port]

Mode [NORMAL]

Serial number :

R101111

Article number :

R9840xxx

Run time :

10 hours

Remaining run time :

490

hours

Number of strikes :

10

Z_AXIS : 100

Select with

or

then <ENTER>

<EXIT> to return.

Menu 3-4

5. Loosen the lock nut A, securing the position of the adjustable screw (B), on the back of the lamp casing (nutdriver 10).