KPM II Monitor Operation

ROw-BY-ROw ALARM LEVEL SETTING

(Requires Version V2.05 Or Higher Software -

KPM II Stack-Mode Monitors Only)

This feature allows the audio alarm to be disabled on

selected rows in applications such as planting seed

corn.

NOTE: Program system to monitor all planter rows

before performing these steps.

STEP 1 Enter programming mode by pressing and

holding SETUP key. Monitor emits several
short beeps, followed by a long beep. On
the lower LCD, SETUP icon turns on and
arrow head icon flashes, indicating the user
can select an item to program.

NOTE: Monitor must be in a programmable
function (row spacing, unit, speed, volume or
area) to enter setup. Monitor will not enter setup
in seed population or seed spacing.

STEP 2 Press the UP or DOWN arrow keys to move

the flashing arrow to SEED POPULATION.
As the arrow icon moves, the lower LCD
will display the current setting of each item
selected.

12060218

NOTE: SMM console may not be applicable to
all models.

AREA

OK

CLEAR

ON

OFF

ExIT

ENTER

SETUP

ROw

SPACING

TOTAL

AREA

UNITS

SPEED

VOLUME

SCAN

SEED

SPACING

FIELD

AREA

SPACING

TOTAL

SEED

POP.

FIELD

SELECT

SPEED

SCAN

SETUP

REAR

12

11

10

9

8

7

6

5

4

3

2

1

(1314 15 1617 18)

ROw
SETUP

REAR

SEED

POPULATION

SMM

®

®

SETUP

2

1

FRONT

(12

11

10

9

8

7

6

5

4

3

13 14 15 1617 18)

120
110
100
90
80
70
60
%

120
110
100
90
80
70
60
%

KPM II

NOTE: Illustrated using rear/front configuration.
The KPM II Stack-Mode console shows LEFT in
the left/right configuration, REAR in the rear/front
configuration and FRONT LEFT/REAR LEFT in
the four sections configuration. The SMM console
shows RIGHT in the left/right configuration, FRONT
in the rear/front configuration and FRONT RIGHT/
REAR RIGHT in four sections configuration.

Advertising