Lubrication and Maintenance

PISTON PUMP STORAGE

NOTICE

Entrance of air into pump will cause rapid and severe corrosion.
KEEP AIR OUT OF PUMP!

NOTE: SUSPENSION FERTILIZER must be flushed from pump for ANY storage period.

1. Flush pump with 5 to 10 gallons (19 to 38 liters) of fresh water and circulate until all corrosive salts are dissolved in pump.

2. Set pump on 10. Draw in a mixture of half diesel fuel and 10 weight oil until discharge is clean. Plug inlet and
outlet.

Liquid fertilizer piston pump

PREPARING PLANTER FOR STORAGE

•

Store planter in a dry sheltered area if possible. Refer to “Safety Lockups” in Machine Operation section for
proper safety lockup installation during storage.

•

Remove all trash that may be wrapped on sprockets or shafts and remove dirt that can draw and hold
moisture.

•

Clean all drive chains and coat with a rust preventative spray, or remove chains and submerge in oil.

•

Lubricate planter and row units at all lubrication points.

•

Inspect planter for parts that are in need of replacement and order during “off” season.

•

Make sure seed and granular chemical hoppers are empty and clean.

•

Clean seed meters and store in a dry, rodent-free area.

•

Remove seed discs from brush-type seed meters, clean and store meters with discs removed.

•

Grease or paint disc openers/blades and row marker disc blades to prevent rust.

•

Flush liquid fertilizer tanks, hoses and metering pump with clean water. See “Piston Pump Storage” if
applicable.

•

Empty and clean dry fertilizer hoppers. Disassemble and clean metering augers. Reassemble and coat all
metal parts with rust preventative.