Programming - clearing total area, Programming - clearing total area -16 – Kinze 3000 Rigid Frame Planter Rev. 6/14 User Manual

Page 86

Advertising
background image

M0188-01

Model 3000

6-16

Rev. 6/11

TM

KPM II Monitor Operation

NOTE: If a discrepancy occurs and digits must be changed, follow STEPS 1 and 2 to enter the programming mode
and proceed as follows:
•Press the OK key and the flashing arrow becomes solid. The least significant digit of the displayed value will be
blinking.
•This value can be changed by pressing UP or DOWN arrow keys.
•Once digit is correct, press the SELECT key and the blinking digit moves to the next significant digit, where the
process can be repeated.

Pulses per mile or kilometer are limited to a range from 500 PPM (310 PPKM) to 500,000 PPM (310,686 PPKM).

KEY Action

Flashing Digit

Display Value

Press The UP Key

Right Most Digit

203

1, 2032, 2033

Press The SELECT Key

Second Digit From Right

20

33


Press The DOWN Key

Second Digit From Right

20

23, 2013, 2003, 2093, 2083


Press The SELECT Key Twice

Left Most Digit

2083


Press The DOWN Key

Left Most Digit

1083, 0500 (Min. Value), 9500, 8500

•To reset counter, press the UP and DOWN

arrow keys at the same time and hold them

down for a short period of time to clear the

data. The CLEAR? icon will be displayed

and the monitor will beep several times.

When the data is actually cleared, the

monitor will emit a long beep, and the total

area is reset to zeros. After the long beep,

the previous recorded total area is not

retrievable. Once cleared, the user

may not

choose to exit programming mode without

saving as described in STEP 4.

STEP 4 To exit and save, press and hold the OK key.

The monitor emits several short beeps and

SAVE? icon is turned on. After a short time

a long beep is heard, and the lower LCD

will display the word “DONE”. Release the

OK key. If the OK key is released BEFORE

the word “DONE” is displayed, the changes

WILL NOT BE SAVED. The word “DONE”

MUST be displayed in order for the save to

have occurred.

NOTE: Programming mode may be exited at any

tim by pressing the SETUP key. Pressing this

key returns the monitor to its normal operation.

All items changed and saved come into effect

immediately. Any items changed, but not saved

revert to original programmed value.

PROGRAMMING - CLEARING TOTAL AREA

NOTE: Clearing the total area counter will also

clear the field area counter.

STEP 1 To enter the programming mode, press

and hold the SETUP key. The monitor will

emit several short beeps followed by a long

beep. On the lower LCD, the SETUP icon

turns on and the arrow head icon will flash,

indicating that the user can select an item

to program.

NOTE: Monitor must be in a programmable

function (row spacing, units, speed, volume or

area) to enter setup. The monitor will not enter

setup in seed population or seed spacing.

STEP 2 Press tUP or DOWN arrow keys to move

flashing arrow to TOTAL AREA. As the arrow

icon moves, the lower LCD will display the

current setting of the item selected.

STEP 3 Press the OK key and flashing arrow

becomes solid and audible alarm sounds.

•The lower LCD will display the total area

and the ACRE (or Ha) icon turns on.

•With the flashing arrow on TOTAL AREA,

press the OK key.

Advertising