Electrical installation

Control terminals

5

l

110

EDKCSCX064 DE/EN/FR 4.0

5.3

Control terminals

ECSXA070

Fig. 5−5

Plug connectors for control terminals (X6)

For the supply of the control electronics an external 24 V DC voltage at terminals
X6/+24 and X6/GND is required.

(

Stop!

ƒ

The control cables must always be shielded to prevent
interference injections.

ƒ

The voltage difference between X6/AG, X6/GND and PE of the
axis module may maximally amount to 50 V.

ƒ

The voltage difference can be limited by:
– overvoltage−limiting components or
– direct connection of X6/AG and X6/GND to PE.

ƒ

The wiring has to ensure that for X6/DO1 = 0 (LOW level) the
connected axis modules do not draw energy from the DC bus.
Otherwise, the power supply module may be damaged.