Mounting in cold-plate design, Mounting in cold−plate design, Mechanical installation – Lenze ECSCx Axis cold plate User Manual

Page 94

Advertising
background image

Mechanical installation

Mounting in cold−plate design

4

l

94

EDKCSCX064 DE/EN/FR 4.0

4.2

Mounting in cold−plate design

The axis modules ECSC... are intended for mounting in cold−plate design (e.g. on
collective coolers).

Requirements for collective coolers
The following requirements must be met to ensure a safe operation of the axis
modules:

ƒ

Good thermal contact with the cooler

–

The contact surface between collective cooler and axis module must be
at least as large as the cooling plate of the axis module.

–

Smooth contact surface, max. deviation 0.05 mm.

–

Connect the collective cooler with all specified screwed connections to
the axis module.

ƒ

Maintain the thermal resistance R

th

according to the table.

–

The values apply for operating the axis modules under rated conditions.

Axis
module

Power to be dissipated

Heat sink − environment

Type

Ploss [W]

R

th

[k/W]

ECSC

L004

14.0

0.31

ECSC

L008

29.0

ECSC

L016

64.0

ECSC

L032

117.0

0.13

ECSC

L048

132.0

ECSC

L064

158.0

0.11

L Application software:

S = Speed & Torque

P = Posi & Shaft

M = Motion

A = Application

ƒ

Ambient conditions:

–

Furthermore the rated data regarding the ambient temperature and
the derating factors at increased temperature apply to the axis modules
(

^ 89 et seqq.).

–

Temperature of the cooling plate ("Cold Plate"): max. +85 °C