Electrical installation – Lenze ECSCx Axis cold plate User Manual

Page 133

Advertising
background image

Electrical installation

Wiring of the feedback system

Digital frequency input/output (encoder simulation)

5

l

133

EDKCSCX064 DE/EN/FR 4.0

5.5.3

Digital frequency input/output (encoder simulation)

The digital frequency coupling of ECSxS/P/A axis modules basically is effected
as a master−slave connection via the interface X8. This interface can either be
used as a digital frequency input or as a digital frequency output (e. g. for
encoder simulation) (configuration via C0491).

Features

X8 as digital frequency input

X8 as digital frequency output

l

Input frequency: 0 ... 200 kHz

l

Current consumption: max. 6 mA per
channel

l

Two−track with inverse 5 V signals and zero
track

l

Possible input signals:
– incremental encoder with two 5 V

complementary signals (TTL encoders)
offset by 90°

l

The function of the inputs signals can be set
via C0427.

l

Output frequency: 0 ... 200 kHz

l

Permissible current loading: max. 20 mA per
channel

l

Two−track with inverse 5 V signals (RS422)

l

The function of the output signals can be set
via C0540.

Advertising