Rated data, Technical data – Lenze ECSCx Axis cold plate User Manual

Page 91

Advertising
background image

Technical data

Rated data

3

l

91

EDKCSCX064 DE/EN/FR 4.0

3.2

Rated data

Rated data

Type

Axis module

ECSx

L004

ECSx

L008

ECSx

L016

Output power 400 V mains

S

rated

[kVA]

1.3

2.6

5.3

Data for operation with upstream power supply
module on mains voltage

V

mains

[V]

400

480

400

480

400

480

DC−bus voltage

V

DC−bus

[V]

15 ... 770

DC−bus current

I

DC−bus

[A]

2.5

2.0

4.9

3.9

9.8

7.8

Rated output current at 4 kHz
(causes a heatsink temperature of 70°C at an
ambient temperature of 20°C)

I

r

[A]

2.0

1.6

4.0

3.2

8.0

6.4

Rated output current at 8 kHz

(at an ambient

temperature of 20°C it causes a heatsink
temperature of 70°C)

1)

I

r

[A]

1.4

1.1

2.7

2.2

5.3

4.2

Max. output current
(acceleration current)

I

max

[A]

4.0

8.0

16.0

Continuous current at standstill
(holding current at 90°C, 4 kHz)

I

0,eff 4 kHz

[A]

2.0

1.6

4.0

3.2

8.0

6.4

Short−time standstill current
(holding current at 90 °C, 4 kHz)

2)

I

0,eff 4 kHz

[A]

2.3

4.6

9.1

Short−time standstill current
(holding current at 70 °C, 4 kHz)

2)

I

0,eff 4 kHz

[A]

3.0

6.0

12.0

Short−time standstill current
(holding current at 70 °C, 8 kHz)

2)

I

0,eff 8 kHz

[A]

1.5

3.0

6.0

Power loss (operation with
rated current at 4 kHz / 8 kHz)

Total

P

loss

[W]

27.3

46.3

84.7

Inside the

device

13.3

17.3

20.7

Heatsink

14.0

29.0

64.0

Max. output frequency

f

out

[Hz]

600

Mass

m [kg]

approx. 2.4

1)

If the heatsink temperature reaches 70°C, the switching frequency automatically changes to
4 kHz.

2)

The indicated temperature is the measured heatsink temperature (C0061).

L

Application software:

S = Speed & Torque

P = Posi & Shaft

M = Motion

A = Application