Electrical installation – Lenze ECSCx Axis cold plate User Manual

Page 135

Advertising
background image

Electrical installation

Wiring of the feedback system

Digital frequency input/output (encoder simulation)

5

l

135

EDKCSCX064 DE/EN/FR 4.0

ƒ

2 to 3 slaves connected to the master:
Use the EMF2132IB digital frequency distributor to wire the ECS axis
modules with master digital frequency cable EYD0017AxxxxW01W01 and
slave digital frequency cable EYD0017AxxxxW01S01.

X8

X8

X8

X8

0

1

1

1

E-Shaft Master

Slave 3

Slave 2

Slave 1

X

S

PLC

X4

X4

X4

X4

120

ECS

ECS

ECS

ECS

X1

X5

X2 X3 X4

EMF2132IB

120

120

X14

X14

X14

X14

120

120

120

ECSXP001

Fig. 5−16

ECS axis modules in the digital frequency network with digital frequency distributor
EMF2132IB

PLC

Master control (PLC) or a PLC device to control the drive system

E−Shaft
master

Master value master (axis module ECSxP)

Slave 1...3

Slave 1, slave 2, slave 3 (axis module ECSxP)

0

Master digital frequency cable EYD0017AxxxxW01W01 (socket/socket)

1

Slave digital frequency cable EYD0017AxxxxW01S01 (plug/socket)

I

Tip!

"xxxx" in the type designation of the digital frequency cables
serves as a wildcard for the specification of the cable length in
decimetres.

Example: EYD0017A0015W01W01

® cable length = 15 dm

Advertising