3 technical data, 1 general data and operating conditions, Technical data – Lenze E931Ex User Manual

Page 15: General data and operating conditions, 3technical data

Advertising
background image

Technical data

General data and operating conditions

3

l

15

GHB 13.0001−EN EN 3.0

3

Technical data

3.1

General data and operating conditions

Conformity

CE

2006/95/EC

Low-Voltage Directive

Regulations

EN 61800−3

Interference level B

Climatic conditions

Air humidity max. 90 % without condensation

Cooling

Passively via housing surface and rear panel

Admissible temperature range

Transport

−25 °C... +70 °C

Storage

−25 °C... +70 °C

Operation

0 °C ... +50 °C

above +40 °C, reduce the power by 20 W/°C

Permissible installation height

0 ... 1000 m amsl

above 1000 m amsl, reduce the rated output
current by 5 %/1000 m

Mounting position

Vertical

Installation clearances

above/below

³ 100 mm

sidewise

Directly alignable

Monitoring

Overvoltage / undervoltage in the DC bus, overcurrent or short
circuit of the output stage, motor temperature and output stage
temperature, I

2x

t−monitoring of the motor, encoder monitoring

Type of protection

IP 20

Inputs

6 digital inputs, 2 analog inputs
(adjustable via software)

Outputs

2 digital outputs, 2 analog outputs
(adjustable via software)

Memory cards

Multimedia card